Classification and Characteristics
|
Product Name |
HEADWAY Reagent Kit for Ballast Water Instrumentation |
|
Compatible System |
HEADWAY OceanGuard® BWMS Ballast Water Monitoring Unit |
|
Composition |
DPD Chemical Agent Bottle, Indicator Bottle, Buffer Bottle + SDS Document |
|
Test Principle |
DPD Colorimetric Method for TRO (Total Residual Oxidant) |
|
Test Range |
TRO: 0 ~ 5 mg/L (Typical for BWMS) |
|
Storage Condition |
Store in cool, dry & dark place, 5~25℃, away from sunlight |
|
Shelf Life |
12 Months under proper storage |
|
Application Medium |
Seawater / Ballast Water |
|
Certification |
Meet IMO D-2 testing requirement, with SDS safety sheet |
|
Power Note |
Reagent consumable, no power consumption |
Ballast Total Chlorine Reagent Kit
Features: These pre-mixed liquid reagents are designed for accurate and reliable measurement of total chlorine levels, critical for effective ballast water management. They come in supply quantities of 30 days, 60 days, or a full 12 months to meet diverse operational needs. The kit uses the DPD method accepted by the USEPA for analyzing total residual chlorine, meeting strict regulatory standards and ensuring compliance with environmental protocols.
Kit Contents: Includes Total Chlorine Buffer Solution, DPD Powder for Chlorine Analyzers, and Total Chlorine Indicator.
Ballast Water Test Kit
Features: Developed to ensure ballast water is as safe and hygienic as possible, the kit helps user companies comply with current and future legislation and guidelines. It enables timely, efficient, and safe ballast water exchange while providing effective monitoring. The kit includes a portable incubator, UV lamp, salinity refractometer, and various bacterial test reagents.
When selecting a ballast water instrumentation reagent kit, factors such as the instrument model, testing parameters, operational convenience, shelf life, and storage conditions should be considered based on specific needs. Additionally, it is essential to ensure the kit meets relevant regulatory standards and requirements to guarantee the normal operation of ballast water systems and effective water quality monitoring.
Advantages
1. Genuine matched reagent, factory pre-calibrated for HEADWAY OceanGuard monitor, stable test data, low
deviation.
2. Standard DPD formula, comply with marine ballast water TRO test specification accepted by classification
societies.
3. Complete set with buffer + indicator + DPD agent, one kit for full testing, no separate purchase.
4. Formulated for high-salinity seawater, anti-interference to turbidity and marine matrix.
5. Long shelf life, stable color reaction performance, convenient for ship stock & spare.
6. Complete SDS safety document, easy for vessel ISM / PSC inspection.
7. Liquid & solid reagent well sealed, anti-leakage package for marine transportation.
Replacing or Installing the Reagents procedure
1. Reagent Preparation
There are two reagents required, and supplied in each kit; the buffer and the indicator. 
The buffer and indicator reagents are provided as dry reagents and require the addition of deionized water (or pure water). You will need to have about 500ml of deionized water on hand prior to preparing the buffer solution and about 200ml of deionized water for the indicator. Allow about ½ hour time to prepare the reagents.
NOTICE: Use caution while preparing. These reagents are caustic and can burn skin and stain clothing. The use of protective gloves, clothing and eye protection is highly recommended.
Buffer Reagent Preparation
Add about 400 ml of deionized water into the buffer bottle. Cap tightly and shake vigorously until the powder is fully dissolved. When fully dissolved add enough deionized water to bring the volume in the bottle up to the fill line (or the knee of the bottle neck).
NOTICE: Replacing Buffer Reagent should be taken every one year.
Indicator Reagent Preparation
The indicator reagents are packed in a small snap lid case. Open the case and remove one indicator bottle (small white bottle) and one brown DPD tube.
Add about 100ml of deionized water into one of the 125 ml indicator bottle. Cap tightly and shake vigorously until the powder is dissolved. Remove the cap and add the contents of the DPD powder bottle (small brown tube). Cap and shake to fully dissolve the powder. When fully dissolved add enough deionized water to bring the
volume in the bottle up to the knee of the bottle neck. More complete instructions are included in the reagent kit.
NOTICE: Replacing Indicator Reagent should be taken every 3 month.
Once mixed, the indicator reagent has an expected life of 90 days if kept under 25°C and 30 days if kept under 40°C. Write the mixing date on the reagent bottle labels in the area provided. Dispose of expired reagents correctly.
2. Replacing Reagent Procedure
The time interval between replacing reagent operation and starting ballast pump (make sure ballast water flow into the TRO meter) should not be more than one hour. If not, the glass cuvette in the TRO Meter may be dyed by the reagents, resulting in the fault TRO reading.
NOTICE: The replacing reagent procedure could be only taken in “Ballast on” or “Deballast on” status, while the ballast pump is off.
Working Principle
The kit adopts standard DPD (N,N-Diethyl-p-phenylenediamine) colorimetric method. Under the fixed pH condition maintained by buffer solution, DPD chemical agent reacts with Total Residual Oxidant (TRO) in ballast water and generates stable magenta/pink chromophore. The indicator assists reaction stabilization. The built-in photometer of HEADWAY ballast water instrument detects absorbance at fixed wavelength, and calculates TRO concentration by calibration curve. The TRO value reflects the residual oxidant level after ballast water treatment, to judge whether the discharge meets IMO regulation.
Application
1. On-line TRO monitoring for HEADWAY OceanGuard BWMS (Ballast Water Management System) on ocean-going cargo ships, container ships, bulk carriers, tankers.
2. Spot sampling test of ballast water before discharge, PSC / port state inspection compliance verification.
3. Daily routine operation check & performance verification of BWMS treatment effect.
4. Laboratory / ship board test for residual oxidant in seawater after electro-catalytic oxidation treatment.
5. Fleet spare consumable stock for ship management companies.
Maintenance
1. Keep reagent bottles tightly closed after use, avoid air exposure and cross-contamination.
2. Store in designated cool dark chemical cabinet on vessel, strictly separate from strong acid, reducing agent.
3. Check appearance and expiry date before use. Discard if liquid discoloration, precipitation or leakage occurs.
4. Do not transfer reagent to other unmarked bottles. Follow SDS when handling.
5. Clean instrument flow cell regularly as per instrument manual to avoid color cross-contamination.
6. Wear PPE (gloves, goggles) during operation. Avoid skin & eye contact.
Spare & Order Information
- SKU: HEADWAY-DPD-KIT
- Matching spare: full set reagent kit (DPD agent + indicator + buffer)
- Replacement cycle: Depends on vessel BWMS running hours; normally 3–12 months per kit for single vessel.
- Reminder: Always keep spare kit on board for PSC inspection.
- Compatible only with HEADWAY original ballast water TRO monitor. Not universal for other brand BWMS
analyzer.
Acceptance Standard
1. Visual check: All bottles intact, no leakage, label clear, SDS document complete.
2. Check production batch & expiry date as stated.
3. Matching test on HEADWAY instrument: Test with standard TRO sample, reading error within allowable
tolerance.
4. Package: Anti-leak packaging, suitable for marine shipment.
5. Acceptance reject condition: Bottle broken, leakage, expired, obvious precipitation, missing SDS.
FAQ
Q1: Is this reagent kit original for HEADWAY OceanGuard BWMS?
A1: Yes, this is the matched reagent set specially calibrated for HEADWAY OceanGuard ballast water instrumentation.
Q2: Can this kit work for other brand BWMS monitor?
A2: Not recommended. The formula and concentration are calibrated for HEADWAY analyzer, test result may be inaccurate on other brands.
Q3: What is TRO, why we need to test it for ballast water?
A3: TRO = Total Residual Oxidant. It is the key parameter to verify the disinfection effect of electro-catalytic BWMS, required for IMO D-2 compliance and PSC inspection.
Q4: How to store the reagent on ship?
A4: Keep cool, dark, 5~25℃, away from sunshine, heat source, incompatible chemicals. Seal bottles after every use.
Q5: How long is the shelf life?
A5: 12 months from production date under proper storage condition.
Q6: Do you provide MSDS/SDS document?
A6: Yes, each kit comes with SDS safety data sheet for marine inspection.